frogBoxHeat
frogBoxHeat
Smart heating controller for up to 11 heating circuits/rooms for connecting underfloor heating, classic and electric radiators.
With the multi-channel heating controller frogHeat (supply: 110-240 V~) up to five thermal heating valves or electric radiators can be connected directly to 5 potential-free (in 3 galvanically separated circuits) relay outputs.
Additionally six outputs can be controlled virtually via the frogblue Bluetooth® mesh network to control e.g. a thermal heating valve directly at the radiator via e.g. a frogAct1-1. Five pump circuits can be requested separately. This happens automatically, depending on whether one of the assigned valves is opened.
Furthermore, a heating request is made automatically if a heating phase is detected in a heating circuit. If supported by the heating system, it is also possible to switch to cooling mode. For this purpose, a signal is sent to the heating system and the control is adjusted accordingly.
If the TARGET or ACTUAL temperature should ever not be available, the frogHeat automatically switches to emergency operation and ensures that the temperature does not drop too much. To prevent the pipes from clogging, a flushing mode can be set that opens the valves repeatedly without switching on the heating.
- Mains voltage : AC 110–240 V~
- Mains frequency : 50 / 60 Hz
- Stand-by Consumption : Less than 200 mW (without illumination)
- WLAN : No
- Bluetooth® : Bluetooth® 4.2 Low Energy
- Frequency range: 2400-2483,5 MHz max. 5.0 dBm
- Typical radio open field range : 30 metres
- Ambient temperature : -25°C to +60°C
- Storage temperature : -25°C to +70°C
- Air humidity (during operation) : (Non-condensing)
- IP protection class : IP56
- Contact type : μ, N/O contact
- Connection variants : 230V, Push-buttons, switches, heating valves, electric radiators
- Connection type : Screw terminal (single wire)
- Core cross section : 1 - 1,5 mm2 (rigid, flexible with ferrule)
- Stripping length : 7 mm
- Quantity cable feed : 2 (max. NYM-J 5 x 1,5mm2 )
- Inputs : 2 (AC 110-240V ~)
- Outputs : 5 potential-free (in 3 galvanically isolated circuits)
- Virtual outputs : 6; e.g. frogAct1-1
- Outputs dimmable : No
- Minimum load : -
- Maximum power LV : max. 6 A / 30 V DC
- Maximum power HV : max. 6 A / 110-240 V AC
- Certifications : Bluetooth®
- Integrated Logic module : Yes
- Configuration backup : Yes
- Comfort and timer functions : Yes
- Power measurement : No
- Temperature sensor : Yes
- Dimensions (L x B x H) : 115 x 115 x 40 mm (without gasket)
- Dimensions (L x B x H) : 115 x 115 x 44 mm (with gasket)
- Weight : 315 g
- Packaging dimensions (L x B x H) 1 unit : 130 x 140 x 75 mm
- Weight including packaging 1 unit : 432 g